Page #26 background imageLoading...
Page #26 background image
Pump Installation 5150 Pump Installation
EN EN
Sun Sensor
module
remote switch
(oat switch)
water meter
grounding rod
PSk3
controller
PV disconnect
safety rope
8.2 Submersible Pumps
8.2 .1 System Layout: Submersible Pumps
ow sleeve
PV generator
a
CAUTION – This graphic is an example
pump system layout diagram and for
ease of understanding only. For system
installation and wiring read and follow
the detailed instructions given in this
manual.
8.1.2 Cable Splicing
To connect the motor cable with a cable extension
you should connect the cable ends with a splicing kit.
It is very important that the cable joints are fully
sealed otherwise moisture could cause a short
circuit. This will damage the pump system.
For more information about connecting cable
ends with a splicing kit see the “submersible cable
splicing” manual in the package of the splicing kit.
a
CAUTION – Cable splice failures are
a common source of errors. Check the
splice for proper connections.
CAUTION – Bad cable splicing can
damage the controller and/or the pump.
Such damage is excluded from the
warranty.
For surface pumps:
Figure 17: Prevent air locks in pipes
Figure 18: Avoid sharp 90° elbows and size adaptors
submersible pump
liquid level sensor
well probe
splicing kit
pressure sensor