EasyManua.ls Logo

LP Technologies LPT-3000 - 6-1. Specifications

LP Technologies LPT-3000
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page | 68
Chapter 6. Options
6-1. Specifications
Opt
-
1
: TRACKING GENERATOR
Scope of Frequency : 100 kHz ~ 3 GHz
Scope of the Amplitude : 0 dBm ~ -50 dBm
Accuracy of the Amplitude : ±3 dB, Typically ±1.5 dB
Flatness of the Amplitude : ±2 dB, Typically ±1.5 dB
Distortion of Harmonics : <-20 dBc (10 MHz ~ 2.8 GHz), Typically <-30 dBc
Reverse Power : +30 dBm
Impedance : 50Ω nominal
Connector : N-type Female
RF Input VSWR : <1.5 : 1
Opt-2
: CDMA(CDMA2000 ; Pilot Channel, WCDMA ; 1 CPICH) Signal Generator
Opt-3
: GPIB interface
IEEE 488 Bus
Opt-4
: ETHERNET interface ; for Internet Remote Control
Opt-5
: SOFT CARRYING CASE
Opt-6
: General KIT SET
SMA-N adapter × 2
10 dB attenuator × 1, 20dB attenuator × 1
RF cable (SMA-SMA, RD316, 300 mm) × 2
Kit box × 1
Opt-7
: CATV KIT SET
N-BNC adapter × 2
50Ω ~ 75Ω adapter × 2

Related product manuals