6-1. Specifications
►
Opt
-
1
: TRACKING GENERATOR
Scope of Frequency : 100 kHz ~ 3 GHz
Scope of the Amplitude : 0 dBm ~ -50 dBm
Accuracy of the Amplitude : ±3 dB, Typically ±1.5 dB
Flatness of the Amplitude : ±2 dB, Typically ±1.5 dB
Distortion of Harmonics : <-20 dBc (10 MHz ~ 2.8 GHz), Typically <-30 dBc
Reverse Power : +30 dBm
Impedance : 50Ω nominal
Connector : N-type Female
RF Input VSWR : <1.5 : 1
► Opt-2
: CDMA(CDMA2000 ; Pilot Channel, WCDMA ; 1 CPICH) Signal Generator
► Opt-3
: GPIB interface
IEEE 488 Bus
► Opt-4
: ETHERNET interface ; for Internet Remote Control
► Opt-5
: SOFT CARRYING CASE
► Opt-6
: General KIT SET
SMA-N adapter × 2
10 dB attenuator × 1, 20dB attenuator × 1
RF cable (SMA-SMA, RD316, 300 mm) × 2
Kit box × 1
► Opt-7
: CATV KIT SET
N-BNC adapter × 2
50Ω ~ 75Ω adapter × 2