5
MERLIN LEGEND R6 DESIGN IMPLEMENTATION GUIDE (CONTINUED)
Customer Name: __________________________________ Node: ________
Public Switched Telephone Network lines:
Loop Start/Ground Start
Trk IDs Pool Type COMMENTS
DID - Are DIDs connected to this system routing calls to non-local extensions? Y / N.
If yes, Local DID number range _________________________ .
Non-Local DID number range _____________________ .
Are DIDs connected to another system routing calls to this system? Y / N.
If yes, on what Node are the DIDs connected _______________ .
COMMENTS
Trk IDs Block Type ExpDig DelDig AddDig
Tie Trunks (Analog) or (Digital)
Trk IDs Pool Dir InType OutType E&M Sig InMode OutMode DialTone
NOTE: If analog E&M Tie Lines are used to interconnect systems, calls can only go
over two hops, due to call setup time and transmission issues.
100D - DS1 (T1 - PRI)
Slot Type
T1/PRI rbs/com p/s/t lp/loc1–5D4/esf zcs/b8zs
Format Supp Signal LnComp ClkSync Src *SwType
* 4E=4ESS, 5E=5ESS, 100=DMS100, 250=DMS250, DEX=DEX600E,
LN=Legend-NTWK, LP=Legend-PBX
NOTE: When ordering point-to-point T1, parameters must be designated. We
recommend ESF framing and B8ZS zero code suppression.