MERLIN LEGENDCommunications System Release 6.1
System Planning
555-661-112
Issue 1
August 1998
Control Unit Configuration
Page 2-26Numbering the System
2
In Release 5.0 and later, if you want Computer Telephony Integration (CTI)
capability, you must assign an MLX jack (port) as the CTI link. In Release 5.0 and
later, the CTI link communicates with the PassageWay Telephony Services for
Netware product implemented on a server running Netware 3.12 or 4.1 or later. In
Release 6.1 and later, the CTI link may communicate with either the CentreVu
Computer-Telephony Release 3.1 or later on a server running Windows NT 4.0
Server or Windows NT 4.0 Workstation, or PassageWay Telephony Services for
Netware, to provide CTI services.
These CTI services enable a desktop computer running a certified PC application
to provide computer-based features to users. The CTI link port must be selected
from ports 2, 3, 4, 6, 7, or 8. The CTI link port cannot be the potential operator port
or the console programming port.
Planning Form Instructions 2
Use the floor plan and Equipment List (if available) to verify the location of any
video stations and all remaining MLX telephones and adjuncts connected to them.
1. On Form 2a, mark the extension jack assignments for the video stations
and the remaining MLX telephones:
a. In the Jack Type column, make sure D is checked next to the logical
ID for each digital extension jack.
b. In the Person, Location, or Function column, identify each video
station or MLX telephone by the user’s name, location, or function.
c. If an extension port will be a CTI link, Write
CTI Link in the Person,
Location, or Function column, and Label column, and put a check
mark in the CTI Link column. If this is a CTI link, skip to Step 3. The
CTI link port must be selected from ports 2, 3, 4, 6, 7, or 8. The CTI
link port cannot be the potential operator port or the console
programming port.
2. Using the information from Form 2a, mark the digital extension adjuncts
and video stations on Form 2b, System Numbering: Digital Adjuncts:
a. Do
one
of the following:
— If the jack does not have an adjunct connected, write
None in
the Adjuncts column and skip to Step 3.
— If an adjunct is connected to the MLX telephone, proceed to
Step b.
b. If an adjunct is connected to the MLX telephone, enter the type of
adjunct (such as
MFM-SAA, MFM-T/R, MFM-DA, ER1000, 7500B,
ASC 25PX/50, or ASC-VSX) in the Adjuncts column.

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals