5.5. Transducer functions
5.5.1. Measurement input
TheP30Utransducerisequippedwithuniversal,configurable
measurement input, which enables to measure direct current, direct
voltage, resistance and temperature from thermocouples and thermi-
stors.Detailedinformationaboutsupportedinputsisshownintable48.
InputtypeRS-485isaspecialtypeofinput,inwhichtransducertreats
valueformregister8000asameasuredvalue.Valueinregister8000
dependson
RS-485
interfaceworkingmode(Slave,MonitororMaster)
andcanbewritten,monitoredorreadviaRS-485interface.
5.5.1.1. Interface RS-485 Master mode
RS-485interfacecanworkinMastermode,inwhichdevice
isabletoreaddataregistersfromoneslavedeviceconnectedtotrans-
ducer. Both devices must have the same communication parameters.
TheRS-485Mastermodeisswitchedonbyselectingtheappropriate
mode of RS-485 interface from menu: Mbus 485 Mode