17 Ni1000-LG-60...180ºC
18 Cu100-50...180ºC
19 Voltage-5...20mV
20 Voltage-75...75mV
21 Voltage-200...200mV
22 ThermocoupleJ0...400ºC
23 ThermocoupleJ-200...1200ºC
24 ThermocoupleK0...400ºC
25 ThermocoupleK-200...1370ºC
26 ThermocoupleS0...1760ºC
27 ThermocoupleN-20...420ºC
28 ThermocoupleN-200...1300ºC
29 ThermocoupleE-40...260ºC
30 ThermocoupleE-200...1000ºC
31 ThermocoupleR0...1760ºC
32 ThermocoupleT-200...400ºC
33 ThermocoupleB400...1800ºC
34 RS-485mode
4001
AvgTime
w/
r
75...20000 1000 Averagingtimeofthemeasuredvalue[ms]
4002
Point No
w/
r
1...21 1 Number of individual characteristics pointst.
For the value of 1 individual characteristic is
switched off. Sections of individual characte-
ristic are defined with Xn and Yn parameters,
wheren–pointnumber.
4003
Compens.
w/
r
0...1 1 Compensationtypeof:
-coldjunctiontemperatureforthermocouples
- cords resistance for measuring resistance
andtemperaturefromthermistorsensors
Value Description
1 Automaticcompensation
0 Manualcompensation(compensation
valueshouldbewritteninto7668register)