TROUBLESHOOTING
Poco Digital Lighting Controller
PROBLEM
No lights on Poco.
No lights on Channel 1, 2, 3 or 4.
Red light on Channel 1, 2, 3, or 4.
Channel light solid Orange .
Channel light ashes Orange .
Status light on Poco not blinking or Aqua.
Multi-Functional Display (MFD)
PROBLEM
MFD Not displaying Poco icon
CAUSE
Poco is not receiving required power.
Channel is not receiving power.
Power is supplied to Channel from fuse/
breaker panel.
Channel dimmed through PWM .
Poco Data is being transmitted .
Poco may be frozen due to a corrupted
conguration or rmware update.
CAUSE
Check ethernet connection between Poco
& MFD. A ashing green light on Ethernet
cable indicates data is being transmitted
from Poco to the MFD.
SOLUTION
- Check power for 10-30 VDC.
- Check fuse is not blown.
- Check GRND wire.
- Check power for 10-30 VDC.
- Check fuse is not blown.
- Check GRND wire.
Turn a light on that channel off/on. The red
light should ash amber and turn green.
You will have to create Light Groups and
Switches in the conguration menu to
test this capability if they are not already
congured.
Poco factory reset needed. See reset
modes section in manual.
SOLUTION
Ensure MFD Ethernet port is working.
Change Ethernet to a known working port
Update MFD to latest version of rmware.
Troubleshooting
Troubleshooting continued...
Specications
Installation
Interface
Setup
TroubleShooting
Updates
Quick Start