User Manual CM-CAN1
5-5
5 Control and reference input
DE
EN
1
2
3
4
5
6
7
A
Additional explanatory notes to Table 5.2
1) Corresponds to activation by way of terminal in accordance with application data set
DRV_5 or ROT_3; see Application Manual. The activation in this case is delivered only
via the control word of the CAN bus. In the reference structure of the CDA3000 the
function is activated by setting 280 -RSSL1 = TBSEL (7). Direct reference input is
then not possible.
2) Function only active with setting 651-CDSSL = (6) OPTN2. The bit can be used to
switch between characteristic data sets 1 and 2. For more detailed information on
characteristic data set switchover refer to the Application Manual.
3) The CDA3000 offers the possibility of storing four complete parameter sets (user
modes). You can switch between the user data sets by setting 166-UDSSL = (3)
OPTN2 by way of the CAN control word. The switchover can only be made in
STANDBY (power stage not active)
.
Note: For more information on the setting and availability of these
functions refer to the Application Manual.