5.20 Program Function Relay 2 / K26 Relay (RX)
1) Press “” button to enter Function Relay 2 setting.
2) Press “” and “” button to scroll and select.
3) Exit Program Function Relay 2 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY2”.
4) Press “” and “” button to scroll through other Flex EX2 settings.
--- : START function only.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
S/P : FUNCTION relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT : FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B : FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : FUNCTION relay closes for up to 3 seconds when START command is initiated
at transmitter power on and then becomes normal momentary outputs thereafter.
G SENSOR : FUNCTION relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.
RS : For RS system, the function relay works simultaneously with the Select pushbutton.
5.21 Program Function Relay 3 / K30 Relay (RX)
1) Press “” button to enter Function Relay 3 setting.
2) Press “” and “” button to scroll and select.
3) Exit Program Function Relay 3 by pressing the “BACK” button until the
cursor is shown next to “FUNC RLY3”.
4) Press “” and “” button to scroll through other Flex EX2 settings.
--- : START function only.
LV : Function relay closes when receiver voltage is low.
ID : Function relay works simultaneously with all motion commands.
NORMAL : START function + AUX with normal momentary output.
TOGGLE : START function + AUX with toggled/latching output.
TOG&E : START function + AUX with toggled/latching output. The relay opens when
STOP button is pressed down and transmitter power off.
S/P : FUNCTION relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT : FUNCTION relay works simultaneously with the receiver MAIN relays.
TDM A+B : FUNCTION relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN : FUNCTION relay closes for up to 3 seconds when START command is initiated
at transmitter power on and then becomes normal momentary outputs thereafter.
G SENSOR : FUNCTION relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.
RS : For RS system, the function relay works simultaneously with the Select pushbutton.

Table of Contents

Other manuals for Magnetek FLEX EX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Magnetek FLEX EX2 and is the answer not in the manual?

Magnetek FLEX EX2 Specifications

General IconGeneral
Protection RatingIP66
DimensionsVaries by model
WeightVaries by model
Battery TypeAA Alkaline
Operating Temperature-20°C to +55°C
EnclosurePlastic
Battery LifeUp to 100 hours

Related product manuals