25
BE 57-660 Eclipse Model 700 Guided Wave Radar Transmitter
2
.6.5 Model 700 Configuration Menu — Device Setup
Home Screen
Main Menu
Device Setup
Q
uick Start
Identity
Basic Config
I
/O Config
D
isplay Config
Advanced Config
F
actory Config
Quick Start
Identity
Basis Config
I/O Config
Display Config
Advanced Config
Factory Config
Product Name (read only)
Magnetrol S/N (read only)
Hardware Version (read only)
Firmware Version (read only)
LongTag
Probe Length:
30 cm to 30 m
(12 inches to 100 feet)
Level Offset:
-7.6 m to 22.9 m
(-25 feet to +75 feet)
Dielectric Range:
Below 1.7
1.7 to 3.0
3.0 to 10
Above 10
L
evel Offset:
-
7.6 m to 22.9 m
(
-25 feet to +75 feet)
D
ielectric Range:
B
elow 1.7
1.7 to 3.0
3.0 to 10
A
bove 10
4 mA Set Point (LRV):
-
7.6 m to 53 m
(
-25 feet to +175 feet)
20 mA Set Point (URV):
-
7,6 m to 53 m
(
-25 feet to +175 feet)
Failure Alarm:
2
2 mA
3
,6 mA
Hold
Level Units:
Inches
Feet
Millimeters
Centimeters
Meters
Probe Model:
7zF Sngl Rod Tanks
7zP Coax HP
7zT Coax Std
7z1 Sngl Flex Std
Probe Coating: (7zF only)
None (Bare)
PFA Coated
Probe Mount:
NPT
BSP
Flange
L
evel Units:
I
nches
F
eet
Millimeters
C
entimeters
M
eters
Probe Model:
7
zF Sngl Rod Tanks
7
zP Coax HP
7zT Coax Std
7
z1 Sngl Flex Std
Probe Mount:
NPT
B
SP
F
lange
Probe Length:
3
0 cm to 30 m
(
12 inches to 100 feet)
Measurement Type:
Level Only
Interface and Level
Interface and Volume
Volume and Level
Flow
Home Screen
Main Menu
Device Setup