72
BE 57-660 Eclipse Model 700 Guided Wave Radar Transmitter
3
.7.3 Enlarged Coaxial Probe
1 | TECHNOLOGY
2
| MEASUREMENT SYSTEM
3 | CONFIGURATION/STYLE (RIGID)
7
7 ECLIPSE GWR Probes - Model 700
B English (inches)
D Metric (centimeters)
P Enlarged Coaxial, High Pressure: Overfill w/Glass Seal (+200 °C/+400 °F) Available only with 10th digit N
T Enlarged Coaxial, Overfill Standard O-Ring Seal (+200 °C/+400 °F) NOT available with 10th digit N
4 5 | PROCESS CONNECTION SIZE/TYPE (consult factory for other process connections)
Threaded
ASME Flanges
4 3
2" 150# ASME RF ¿
4 4
2" 300# ASME RF ¿
4 5
2" 600# ASME RF ¿
4 K
2" 600# ASME RTJ ¿
5 3 3" 150# ASME RF
5 4 3" 300# ASME RF
5 5
3" 600# ASME RF
56
3" 900# ASME RF
57
3" 1500# ASME RF
58
3" 2500# ASME RF
5K
3" 600# ASME RTJ
5L
3" 900# ASME RTJ
4 1
2" NPT Thread ¿
5M 3" 1500# ASME RTJ
5N
3" 2500# ASME RTJ
6 3
4" 150# ASME RF
6 4
4" 300# ASME RF
6 5
4" 600# ASME RF
6 6
4" 900# ASME RF
6 7
4" 1500# ASME RF
6 8
4" 2500# ASME RF
6K
4" 600# ASME RTJ
6L
4" 900# ASME RTJ
6M
4" 1500# ASME RTJ
6N 4" 2500# ASME RTJ
EN Flanges
D W
DN 50, PN 16 EN 1092-1 TYPE B1¿
D Z
DN 50, PN 25/40 EN 1092-1 TYPE B1¿
D D
DN 50, PN 63 EN 1092-1 TYPE B2¿
D E
DN 50, PN 100 EN 1092-1 TYPE B2¿
E W DN 80, PN 16 EN 1092-1 TYPE B1
E Z DN 80, PN 25/40 EN 1092-1 TYPE B1
E D DN 80, PN 63 EN 1092-1 TYPE B2
E E DN 80, PN 100 EN 1092-1 TYPE B2
E F DN 80, PN 160 EN 1092-1 TYPE B2
E G
DN 80, PN 250 EN 1092-1 TYPE B2
E H DN 80, PN 320 EN 1092-1 TYPE B2
E J DN 80, PN 400 EN 1092-1 TYPE B2
F W DN 100, PN 16 EN 1092-1 TYPE B1
F Z DN 100, PN 25/40 EN 1092-1 TYPE B1
F D DN 100, PN 63 EN 1092-1 TYPE B2
F E DN 100, PN 100 EN 1092-1 TYPE B2
F F DN 100, PN 160 EN 1092-1 TYPE B2
F G
DN 100, PN 250 EN 1092-1 TYPE B2
F H
DN 100, PN 320 EN 1092-1 TYPE B2
F J
DN 100, PN 400 EN 1092-1 TYPE B2
4 2
2" BSP (G1) Thread ¿
12 3 456 7 8910 11 12 13 14 15
¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance.

Table of Contents