31
57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA

Dielctrc
(select)
User
 range bounding the dielectric con-
stant of the medium
 from 1.4-1.7, 1.7-3,
3-10, 10-100

Senstvty
xxx
Superuser or
user
 gain value upward or downward
to sense liquid surface
(Superuser password required for dual ele-
ment probes.)

BlockDis
xx.x su
User
 distance below reference point
where level is not sensed
-99.9 to 2286 cm (-39.3 to 900 in)

SftyZone
(select)
User
 behavior when level is sensed in
safety zone
Off, On, Latch
5.0 Model 705 Menu: Step by Step Procedures
The following table describes the software menu displayed
by the Eclipse PROFIBUS PA
TM
transmitter for “Level
Onlymeasurement. Use this table as a step by step guide
to configure the transmitter.
The second column presents the menus shown on the trans-
mitter display. The displays are in the order they would
appear if the arrow keys were used to scroll through the
menu. The numbers on the first column are not shown in
the display. They are only provided as reference.
The third column provides the actions to take when config-
uring the transmitter. Additional information or an explana-
tion of an action is given in the fourth column. (Shaded
sections are factory menu items).
   
*Status*
*Level*
*AI1Lvl*
None
Transmitter Display MeasType = Lvl Only
Level
xxx.x lu
None
Transmitter Display All MeasType selections
LvlUnits
(select)
User
 the Level units
 from cm, inches, feet, meters,
percent
AI1LVl
xx.x%
None
Transmitter Display All MeasType selections
PrbModel
(select)
User
 the type of probe used
Select from 




PrbMount
(select)
User
 the type of probe
mounting
 from NPT, BSP or Flange
MeasType
(select)
User
 type of measurement
 from Lvl Only, Lvl&Vol, Intrface,
Ifc&Vol
SnsrUnit
(select)
User
 the Sensor units
 from cm, inches, feet, meters
Probe Ln
xxx.x su
User
 the exact length
of the probe
11.8 to 900 in (30 to 2286 cm)

PrbLvlUn
User
 Probe Level units
 from cm, inches, feet, meters,
percent

Lvl Ofst
xxx.x plu
User
 desired Level reading when probe
is dry
-90 to 300 in (-228.6 to 762 cm)