TEXT HERE............
39
57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA
™
7.2 Agency Approvals
705-53XX-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D
705-53XX-2XX Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X IP66
Entity/FISCO
705-53XX-3XX Explosion Proof ➀ Class I, Div. 1; Groups B, C & D
705-53XXX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X IP66
7
05-53XX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D
705-53XX-XXX Suitable for: ➁ Class II, Div. 2; Groups F & G T4
Class III, Type 4X IP66
705-53XX-1XX Intrinsically Safe Class I, Div. 1; Groups A, B, C, & D
705-53XX-2XX Class II, Div. 1; Group G T4
Class III, Type 4X
Entity/FISCO
705-53XX-3XX Explosion Proof ➀ Class I, Div. 1; Groups B, C & D
705-53XX-4XX (with Intrinsically Safe probe) Class II, Div. 1; Group G T4
Class III, Type 4X
705-53XX-XXX Non-Incendive Class I, Div. 2; Groups A, B, C, & D
705-53XX-XXX Suitable for: ➁ Class II, Div. 2; Group G T4
Class III, Type 4X
705-53XX-AXX Intrinsically Safe II 1G, EEx ia IIC T4
705-53XX-BXX
705-53XX-CXX Flame Proof ➀ II 1/2G, EEx d [ia] IIC T4
705-53XX-DXX
705-53XX-EXX Non-sparking ➁ II 3G, EEx n II T4..T6
705-53XX-FXX
➀ Factory Sealed: This product has been approved by Factory
Mutual Research (FM), and Canadian Standards Association
(CSA), as a Factory Sealed device.
➁ Measured media inside vessel must be non-flammable only.
These units are in conformity of:
1. The EMC Directive: 89/336/EEC. The units have been
tested to EN 61000-6-2/2001 and EN 61000-6-4/2001.
2. Directive 94/9/EC for equipment or protective system for use
in potentially explosive atmospheres.
0344