47-602 F10 and F50 Flow Switches
25
4.6 Model Numbers
Series J
100 7 +400 +204 .63 1.6 JGF
60 4 +400 +204 .94 2.3 JHF
Bleed Type
60 4 +400 +204 .55 1.4 JJF
Series K 100 7 +400 +204 ——KOF
Non-Bleed 40 3 +400 +204 ——KOH
2" NPT D22 D24 D26 D28 D20
2
1
⁄2" 150 lb. ANSI raised face flange n/a E54 E56 E58 E50
2
1
⁄2" 300 lb. ANSI raised face flange n/a E64 E66 E68 E60
2
1
⁄2" 600 lb. ANSI raised face flange n/a E74 E76 E78 E70
F10-1 Carbon Steel 304 and 316 Stainless Steel 316 Stainless Steel 1000 psig @ +450 °F (69 bar @ +232 °C)
F10-3 304 Stainless Steel 304 and 316 Stainless Steel 316 Stainless Steel 1000 psig @ +450 °F (69 bar @ +232 °C)
F10-4 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 1000 psig @ +450 °F (69 bar @ +232 °C)
Consult factory for flow lines above 10" or larger flange sizes.
➀ Process temperatures based on +100 °F
(+38 °C) ambient.
➁ Uncontrolled housing heater or drain
available in NEMA 4X/7/9 enclosures.
➂ Consult factory for NEMA 4X/7/9 cast iron
housings.
I I
Series B snap +250 (+121)
SPDT BKB BKK BC9
DPDT BNB BNK BF9
Series C snap +450 (+232)
SPDT CKB CKK CC9
DPDT CNB CNK CF9
Series D snap
+250 (+121)
SPDT DKB DKK DC9
for DC current applications DPDT DNB DNK DF9
Series HS 5 amp
SPDT HMJ HMK n/a
hermetically sealed snap +450 (+232)
with wiring leads
DPDT HMS HMT n/a
Series HS 5 amp
SPDT HM3 HM4 HA9
hermetically sealed snap +450 (+232)
with terminal block
DPDT HM7 HM8 HB9
➀
➁ ➂
On flanged models, standoffs are carbon steel with Model F10-1 and 316 stainless steel on Models F10-3 and F10-4.
Consult factory for Steam applications.