Pure Sine Wave Inverter/Charger
MS Series
Owners Manual

Table of Contents

Questions and Answers

  • A
    Alicia BurkeAug 4, 2025
    Why is my Magnum MS2012 Inverter charging at a low rate when connected to AC power?
    • T
      Tony CastroAug 4, 2025
      A low charging rate when connected to AC power can occur if the charge rate is set too low; adjust the charge rate or SHORE settings on the remote. It can also be caused by low AC voltage (less than 90 VAC); in this case, check the AC input wiring.
  • H
    Heather BentonAug 8, 2025
    Why is my Magnum MS2012 Inverter charging at a low rate when using a generator?
    • M
      montesmichaelAug 9, 2025
      A low charging rate when using a generator can be caused by the generator output being too low to power both the load and the charger. Try reducing the load or increasing the generator's RPMs. Also, check the SHORE settings if a remote is connected.
  • E
    edgarnicholsAug 17, 2025
    Why is my Magnum MS2012 Inverter charger not charging?
    • G
      George GoodmanAug 17, 2025
      The charger may not be charging due to several reasons. Check for loose or corroded battery cables and clean/tighten them. The batteries might be defective and need replacement. Verify that the charger settings are correct and ensure the unit is not in charger standby. Also, check that the AC input voltage is correct.
  • A
    Alejandra EdwardsAug 21, 2025
    What to do if my Magnum MS2012 Inverter has low output or surge power and the Green LED is flashing?
    • M
      Matthew NewmanAug 21, 2025
      This issue can arise from several causes: * Loose or corroded battery cables: Clean and tighten all cables. * Low batteries: Recharge or replace the batteries. * Loose AC output connections: Tighten the AC output connections. * Incorrect battery cable length or gauge: Verify the recommended cable lengths and gauges in the manual and replace cables if needed.
  • V
    Vernon GreeneAug 26, 2025
    What does it mean if my Magnum MS2012 Inverter has no output power and the Green LED is flashing?
    • C
      Cynthia LiuAug 26, 2025
      If your inverter has no output power and the green LED is flashing, it means the unit is in Search mode. This usually indicates that the load is too small for the Search mode circuit to detect. To resolve this, turn on a load greater than 5 watts to bring the inverter to full output power, or turn off Search mode using the remote.
  • M
    Matthew HermanAug 30, 2025
    What causes the DC charge voltage to be higher or lower than expected while charging my Magnum Inverter?
    • D
      Daniel PottsAug 30, 2025
      If a Battery Temperature Sensor (BTS) is installed, the DC voltage will increase or decrease depending on the temperature around the BTS. This is normal.
  • D
    David AllenNov 11, 2025
    What to do if my Magnum MS2012 has no output power and the Inverter LED is OFF?
    • K
      Kenneth PetersNov 11, 2025
      First, ensure the inverter is switched ON. If it is, check the battery voltage at the inverter's terminals, as the battery voltage may be too low. Check fuses/circuit-breakers and cable connections. Your batteries may need to be charged; this fault condition will automatically clear when the battery voltage exceeds the LBCI voltage. Alternatively, the battery voltage may be too high; in this case, reduce or turn off any other charger to the inverter batteries to allow the voltage level to drop. It could also be due to an over-temperature condition; reduce the number of electrical loads to avoid a repeat shutdown, and check ventilation around the inverter. It may also be caused by an AC overload condition; reduce the AC loads or remove all AC output wiring and restart the inverter. Finally,...

Summary

Safety Information

General Safety Precautions

Lists essential safety rules for installation, operation, and maintenance of the inverter.

Battery Safety Guidelines

Provides specific safety instructions for handling, installing, and working with batteries.

Introduction

Installation

Wiring the Inverter

Details DC, AC, and general wiring requirements, including sizing and connections.

Grounding Inverters

Explains proper grounding methods for system safety, compliance, and noise reduction.

Final Inspection and Functional Test

Pre-operation checks and steps to verify correct installation and inverter operation.

Operation

Battery Charging Process

Details the multi-stage charging process for optimal battery health and performance.

Protection and Fault Handling

Explains how the inverter protects itself and connected loads from various fault conditions.

Maintenance and Troubleshooting

Troubleshooting Common Issues

Identifies common inverter problems and provides solutions for quick resolution.

Resetting the Inverter

Explains how to perform soft and hard resets to clear faults and restore operation.

Specifications and Optional Equipment

Battery Information

Magnum MS2012 Specifications

General IconGeneral
Continuous Output Power2000W
Input Voltage12 VDC
Output Voltage120 VAC
Output Frequency60 Hz
Efficiency90%
Protection FeaturesOverload, Short Circuit, Low Battery
Operating Temperature-20°C to +60°C

Related product manuals