5. SPECIFICATIONS
Range
AC Current
Measuring Range Resolution
40A
400A
1000A
0 ~ 40.00A
0 ~ 400.0A
0 ~ 1000A
0.01 A
0.1 A
1 A
Accuracy (% of Reading)
± (2.8% + 10 digits)
± (2.8% + 8 digits)
± (3.0% + 8 digits)
Range
DC Voltage
Measuring Range Resolution
400mV
4V
40V
400V
600V
0 ~ 400.0mV
0 ~ 4.000V
0 ~ 40.00V
0 ~ 400.0V
0 ~ 600V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy (% of Reading)
± (0.8% + 2 digits)
± (1.5% + 2 digits)
± (2.0% + 2 digits)
Range
AC Voltage
Measuring Range Resolution
400mV
4V
40V
400V
600V
0 ~ 400.0mV
0 ~ 4.000V
0 ~ 40.00V
0 ~ 400.0V
0 ~ 600V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy (% of Reading)
± (1.0% + 10 digits)
± (1.5% + 8 digits)
± (2.0% + 8 digits)
Range
Resistance
Measuring Range Resolution
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
0 ~ 400.0Ω
0 ~ 4.000kΩ
0 ~ 40.00kΩ
0 ~ 400.0kΩ
0 ~ 4.000MΩ
0 ~ 40.00MΩ
0.1 Ω
1Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
Accuracy (% of Reading)
± (1.0% + 4 digits)
± (1.5% + 2 digits)
± (2.5% + 5 digits)
± (3.5% + 10 digits)
Note: No Autoranging on 400mV AC Range
Range
Frequency
Measuring Range Resolution
4kHz 0 ~ 4.000kHz 0.001 kHz
Accuracy (% of Reading)
± (1.5% + 2 digits)
Sensitivity: 5Vrms min
Range
Temperature
Measuring Range Resolution
ºC
ºF
-40ºC ~ 1000ºC
-40.0ºF ~ 1832ºF
1 ºC
1 ºF
Accuracy (% of Reading)
± (2.5% + 3ºC)
± (2.5% + 5ºF)
6
Capacitance
Range Measuring Range Resolution
4nF
40nF
400nF
4µF
40µF
400µF
4mF
40mF
0 ~ 4.000nF
0 ~ 40.00nF
0 ~ 400.0nF
0 ~ 4.000µF
0 ~ 40.00µF
0 ~ 400.0µF
0 ~ 4.000mF
0 ~ 40.00mF
0.001 nF
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
0.001mF
0.01mF
Accuracy (% of Reading)
± (5.0% + 30 digits)
± (5.0% + 20 digits)
± (3.0% + 5 digits)
± (4.0% + 10 digits)
± (4.5% + 10 digits)
± (5.0% + 10 digits)