3-313-31
F1/1
F1/1
11
F1/3F1/3
44
33
55
F1/2F1/2
22
F - EVERY 2000 HOURS OF SERVICEF - EVERY 2000 HOURS OF SERVICE
Carry out the operations described previously as well as Carry out the operations described previously as well as the following operations.the following operations.
F1 - COOLING LIQUIDF1 - COOLING LIQUID
DRAINDRAIN
These operations are to be carried out if necessary or every two years at the beginning ofThese operations are to be carried out if necessary or every two years at the beginning of
winter. Place the lift truck on winter. Place the lift truck on level ground with the level ground with the I.C. engine stopped and cold.I.C. engine stopped and cold.
DRAINING THE LIQUIDDRAINING THE LIQUID
- Open the I.C. engine bonnet.- Open the I.C. engine bonnet.
-- Place a container under hose 1 (fig. F1/1) on tPlace a container under hose 1 (fig. F1/1) on the radiator and drain plug 2 (fig. F1/2) ofhe radiator and drain plug 2 (fig. F1/2) of
the engine block. Remove the hose and the engine block. Remove the hose and loosen the drain plug.loosen the drain plug.
- Remove filling plug 3 - Remove filling plug 3 (fig. F1/3) of the radiator.(fig. F1/3) of the radiator.
-- Let the cooling circuit dLet the cooling circuit drain entirely while ensuring rain entirely while ensuring that the ports do not get that the ports do not get clogged.clogged.
-- Check the condition of the hosCheck the condition of the hoses as well as the fastenes as well as the fastening devices and change the hosesing devices and change the hoses
if necessary.if necessary.
- Rinse the circuit with clean water and use a cleaning agent if necessary.- Rinse the circuit with clean water and use a cleaning agent if necessary.
FILLING THE LIQUIDFILLING THE LIQUID
-- Refit and tighten the hose 1 (fig. F1/1) and drain plug 2 (fig. F1/Refit and tighten the hose 1 (fig. F1/1) and drain plug 2 (fig. F1/2) (tightening torque 402) (tightening torque 40
N.m).N.m).
-- Slowly fill up the circuit with cooling liquid (see: Slowly fill up the circuit with cooling liquid (see: 3 - MAINTENANCE: LUBRIC3 - MAINTENANCE: LUBRICANTS ANDANTS AND
FUEL) to the middle of gauge 5 (fig. F1/3) through filler port 4 (fig. F1/3).FUEL) to the middle of gauge 5 (fig. F1/3) through filler port 4 (fig. F1/3).
- Put back filling plug 3 (fig. F1/3).- Put back filling plug 3 (fig. F1/3).
- Run the I.C. engine at idle - Run the I.C. engine at idle for a few minutes.for a few minutes.
- Check for any possible leaks.- Check for any possible leaks.
- Check the level and refill if necessary.- Check the level and refill if necessary.
The I.C. engine does not contain any corrosion resistor and must be filled during the The I.C. engine does not contain any corrosion resistor and must be filled during the whole year with awhole year with a
mixture containing 25% of mixture containing 25% of ethylene glycol-based antifreeze.ethylene glycol-based antifreeze.
https://www.forkliftpdfmanuals.com/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitou MLT 845 120 LSU 3-E3 Series and is the answer not in the manual?

Manitou MLT 845 120 LSU 3-E3 Series Specifications

General IconGeneral
BrandManitou
ModelMLT 845 120 LSU 3-E3 Series
CategoryForklifts
LanguageEnglish

Related product manuals