EasyManuals Logo

Manitowoc Grove RT530E-2 User Manual

Manitowoc Grove RT530E-2
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
LUBRICATION RT530E-2 OPERATOR’S MANUAL
5-8 Published 5-3-2016, Control # 555-02
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Axles
6
Axle Tech
Differentials
As seen in
Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
20.8 l
(44 pt)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to bottom of hole
in housing on the
steer cylinder side
NOTE: Lube level close enough to the hole to be seen or touched is not sufficient. It must be level with the hole.
When checking lube level, also check and clean housing breathers.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
CAUTION: If the makeup amount is substantially more than 0.23 liter (0.5 pint), check for leaks.
9
Axle Tech
Planetary Hubs
and Wheel
Bearings
As seen in
Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
3.1 l
(6.5pt)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to the bottom of
the level hole in the
housing with the fill
plug and the oil level
mark horizontal.
CAUTION: Use of non-approved lubricant may damage components and/or invalidate published lubricant intervals.
Reference Only

Table of Contents

Other manuals for Manitowoc Grove RT530E-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT530E-2 and is the answer not in the manual?

Manitowoc Grove RT530E-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT530E-2
CategoryConstruction Equipment
LanguageEnglish

Related product manuals