OPERATOR MANUAL
Supplement
Crane Warm-up Procedures
An untrained operator subjects himself and others to death or
serious injury. Do not operate this crane unless:
You are trained in the safe operation of this crane. Manitowoc is not
responsible for qualifying personnel.
You read, understand, and follow the safety and operating
recommendations contained in the crane manufacturer’s manuals and
load charts, your employer’s work rules, and applicable government
regulations.
You are sure that all safety signs, guards, and other safety features are
in place and in proper condition.
The Operator Manual and Load Chart are in the holder provided on
crane.
DANGER
!
© 2017 Manitowoc
Published 3-30-2017, Control # 516-04
Reference Only

Table of Contents

Other manuals for Manitowoc Grove YB5515-2

Questions and Answers

  • A
    amanda97Aug 15, 2025
    Why is my Manitowoc Grove YB5515-2 Construction Equipment alternator not charging?
    • M
      Morgan HawkinsAug 15, 2025
      Several factors can cause an alternator to not charge. It could be due to a loose or broken alternator belt, in which case you should replace and/or tighten it to specification. Other potential causes include worn brushes, open brush leads or connections, an open circuit, short circuit, or grounded stator winding. A faulty voltage regulator, short circuit or open circuit in rectifier diodes, or an open circuit or short circuit in the rotor winding could also be the reason. Check for incorrectly connected, loose, or broken wires, referring to the wiring diagram for proper connections and repairing or replacing any faulty wires. Lastly, inspect the slip rings for dirt or bad connections, cleaning or repairing them as needed.
  • J
    jill10Aug 18, 2025
    What to do if Manitowoc Grove YB5515-2 Construction Equipment starter motor does not turn?
    • L
      Laura WallaceAug 18, 2025
      If the starter motor isn't turning, begin by checking for open circuits, and cleaning and tightening any dirty or loose connections at the battery and starter. Also, inspect the wiring and connections between the ignition switch and starter solenoid. If connections are good, the starter relay or ignition switch may be faulty and need replacement. Other possible causes include a worn starter motor, a bad starter solenoid, a dead battery (recharge or replace), failure to engage the parking brake, or a bad neutral start relay. If the problem is internal to the engine, consult the engine manual.
  • R
    Robert KelleyAug 21, 2025
    What causes a high charging rate in Manitowoc Grove YB5515-2 Construction Equipment?
    • J
      Jacob WellsAug 21, 2025
      A high charging rate, even when the battery is at full charge, can stem from several issues. Check the battery's electrolyte level and add distilled water if it's low. Inspect the wiring system for faults, repairing or replacing any faulty wiring. Ensure all connections are clean and tight. A malfunctioning voltage regulator can also lead to this problem, requiring replacement.
  • C
    Colleen ReynoldsAug 25, 2025
    Why does my Manitowoc Construction Equipment winch motor run extremely hot?
    • T
      travis52Aug 25, 2025
      A winch motor that runs extremely hot may be due to a long period of operation; cooling-off periods are essential to prevent overheating. It could also be caused by insufficient battery power; check the battery terminal voltage under load and replace the battery if it's 10 volts or less. A bad connection can also cause overheating; check battery cables for corrosion, clean, and grease them.
  • D
    diana65Aug 27, 2025
    Why is my Manitowoc Grove YB5515-2 alternator noisy?
    • V
      Victor JacobsAug 27, 2025
      Alternator noise can arise from a badly worn belt, which should be replaced and adjusted. Misaligned pulleys can also cause noise; align the fan and alternator pulleys. Check for a loose pulley, looking for a broken key or worn keyway, and tighten the pulley nut. Worn bearings or a short in the rectifier diodes within the alternator can also produce noise, requiring replacement or repair of the alternator.
  • D
    Desiree MooreAug 30, 2025
    What causes a low charging rate in Manitowoc Grove YB5515-2?
    • P
      Patricia FernandezAug 30, 2025
      A low charging rate can be attributed to several factors. Check for a loose or worn alternator belt and adjust or replace it as needed. The alternator itself might be faulty, requiring replacement or repair. A bad battery or low electrolyte level can also cause this issue; replace the battery or add distilled water. Look for short circuits in the system and repair them. Other potential causes include a worn alternator, a malfunctioning voltage regulator, or low engine speed. Test, replace or repair the alternator, replace the voltage regulator or run the engine at a higher speed.
  • D
    Donald WillisSep 2, 2025
    What to do if Manitowoc Construction Equipment winch motor runs but drum does not rotate?
    • J
      Jeanne BeardSep 2, 2025
      If the winch motor runs but the drum doesn't rotate, first check if the clutch is not engaged and engage it. If the clutch is engaged, disassemble the hoist to determine the cause and repair it.
  • K
    kathy00Sep 5, 2025
    What to do if Manitowoc Grove YB5515-2 Construction Equipment winch motor will not operate?
    • C
      Chelsey FischerSep 5, 2025
      If the winch motor won't operate, start by checking the solenoid for defects or sticking. Jar the solenoid to free the contacts and test by applying 12 volts to the coil terminal; you should hear a click when energized. Replace the solenoid if necessary. Also, check the control switch and replace it if defective. If the solenoids operate, check the voltage at the armature post; replace the motor if defective. Finally, ensure all connections on the bottom side of the hood and on the motor are tight.
  • J
    johnsonscottSep 8, 2025
    Why does my Manitowoc Grove YB5515-2 winch motor run in only one direction?
    • M
      mark90Sep 8, 2025
      If the winch motor runs in only one direction, the solenoid may be defective or stuck. Try jarring the solenoid to free the contacts and test by applying 12 volts to the coil terminal; you should hear an audible click when energized. If it's still not working, replace the solenoid. Another possible cause is a defective control switch, which should be checked and replaced if necessary.
  • B
    brownmichaelSep 12, 2025
    Why does my Manitowoc Grove YB5515-2 winch motor run with insufficient power?
    • A
      Amber JonesSep 12, 2025
      Insufficient power or slow line speed in a winch motor can be due to insufficient battery power. Check the battery terminal voltage under load; if it's 10 volts or less, replace the battery. A bad connection can also cause this issue; check battery cables for corrosion, clean, and grease them.

Summary

Crane Warm-up Procedures

Engine Warm-up

Procedures for warming up the engine at all temperature ranges.

Transmission Warm-up

Operating and warm-up procedures for the transmission in various conditions.

Hoist Warm-up

Recommended warm-up procedure for hoist operation, especially in cold weather.

Swing Drive and Turntable Bearing Warm-up

Warm-up procedures for swing drive and turntable bearing based on temperature.

Axles Warm-up

Warm-up procedures for axles at very low temperatures.

Hydraulic Oil System Warm-up

Operating limits and warm-up procedures for the hydraulic oil system based on temperature.

Section 2 Safety Information

Crane Stability and Load Charts

Ensuring crane stability and understanding how to use load charts.

Lifting Operations and Travel on Slopes

General procedures for safe lifting and operating the crane on slopes.

Electrocution Hazards and Precautions

Dangers of electrocution and necessary safety precautions when near power lines.

Electrical Contact and Personnel Handling

Actions during electrical contact and requirements for lifting personnel.

Section 3 Operating Controls and Procedures

Crane Level and RCL System

Function of the crane level indicator and the Rated Capacity Limiter system.

Engine Starting and Traveling Procedures

Procedures for starting the engine, jump starting, and traveling with the crane.

Stopping Travel, Outrigger Operation, and Leveling

Procedures for stopping travel, operating outriggers, and leveling the crane.

Boom and Hoist Operation

How to operate boom lift, swing, telescope, and hoist functions.

Load Handling and Slope Travel Practices

General principles for safe load handling and operating the crane on slopes.

Section 4 Capacity Chart

Using the Capacity Chart

How to locate and use the capacity chart for safe lifting.

Determining Lift Capacity

Factors determining lift capacity and how to read the load rating chart.

Section 6 Maintenance

Daily Walk-around Inspection

Daily pre-operation checks including safety devices, ropes, and reeving.

Replacing Engine Oil;Filter and Torque Bolts

Procedure for replacing engine oil and filter, and importance of torque for critical bolts.

Hydraulic Oil and Filter Replacement

Procedure for changing the hydraulic oil and replacing the hydraulic oil filter.

Manitowoc Grove YB5515-2 Specifications

General IconGeneral
BrandManitowoc
ModelGrove YB5515-2
CategoryConstruction Equipment
LanguageEnglish