HARVEST SEQUENCE
5. Water Purge
The air pump(s) (when used) and the harvest valve(s)
open at the beginning of the water purge to divert
refrigerant gas into the evaporator.
The water pump continues to run, and the water dump
valve energizes to purge the water in the water trough.
ICVD Condensing Unit:
When the refrigerant pressure is low enough to open
the fan cycling pressure control the condenser fan
motor stops.
6. Harvest
The air pump(s) (when used) remains energized and
the harvest valve(s) remains open. The refrigerant gas
warms the evaporator causing the cubes to slide, as a
sheet, off the evaporator and into the storage bin.
Single evaporator models - The sliding sheet of
cubes opens the water curtain/ice damper and bin
switch.
The momentary opening and re-closing of the bin
switch will terminate the harvest sequence and return
to the freeze sequence (Step 3 - 4.)
Twin & Quad evaporator models - The sliding sheet
of cubes opens the ice damper and bin switch. The
momentary opening and re-closing of the bin switch
de-energizes the harvest valve for the evaporator.
When all of the bin switches have opened and closed
the ice machine will terminate the harvest sequence
and return to the freeze sequence (Step 3 - 4.)

Table of Contents

Other manuals for Manitowoc Indigo Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo Series and is the answer not in the manual?

Manitowoc Indigo Series Specifications

General IconGeneral
ModelIndigo Series
Ice TypeNugget
Cooling SystemAir-cooled, Water-cooled
Power SupplyVaries by model
MaterialStainless steel exterior
Water Connection1/2" NPT water inlet

Related product manuals