ICE THICKNESS PROBE (HARVEST INITIATION)
FUNCTION
The ice thickness probe senses ice on the evaporator
and signals the control board to start a harvest cycle.
After ice forms on the evaporator, the ice will contact
the ice thickness probe. After 6 - 10 seconds of
continuous contact, a harvest cycle is initiated.
SPECIFICATIONS
Freeze Time Lock-In Feature
The ice machine control system incorporates a freeze
time lock-in feature. This prevents the ice machine
from short cycling in and out of harvest.
The control board locks the ice machine in the freeze
cycle and a harvest cycle can not start for six minutes.
Maximum Freeze Time
The control system includes a built-in safety which will
automatically cycle the ice machine into harvest after
60 minutes in the freeze cycle.
Maximum Temperature
Maximum temperature for the ice thickness probe is
120 degrees F (49 degree’s C). Do not clean probe in
a dishwasher or expose to temperatures above the