166 Part Number Preliminary 6/11
Analyzing Discharge Pressure in the Freeze Cycle
1. Determine the ice machine operating conditions:
Air temp. entering condenser______
Air temp. around ice machine______
Water temp. entering sump trough______
2. Refer to Operating Pressure table (starting on
page 307) for ice machine being checked.
Use the operating conditions determined in step 1
to find the published normal discharge pressures.
Freeze Cycle______
Harvest Cycle______
3. Perform an actual discharge pressure check.
4. Compare the actual discharge pressure (step 3)
with the published discharge pressure (step 2).
The discharge pressure is normal when the actual
pressure falls within the published pressure range
for the ice machine’s operating conditions. It is
normal for the discharge pressure to be higher at
the beginning of the Freeze cycle (when load is
greatest), then drop throughout the Freeze cycle.
Freeze Cycle
psig (kPa)
1 Minute into the
Freeze Cycle __________
Middle of Freeze Cycle __________
End of Freeze Cycle __________

Table of Contents

Other manuals for Manitowoc Indigo Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo Series and is the answer not in the manual?

Manitowoc Indigo Series Specifications

General IconGeneral
ModelIndigo Series
Ice TypeNugget
Cooling SystemAir-cooled, Water-cooled
Power SupplyVaries by model
MaterialStainless steel exterior
Water Connection1/2" NPT water inlet

Related product manuals