FREEZE CYCLE DISCHARGE PRESSURE
LOW CHECKLIST
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
(page 162)
Air Cooled Condensers
Defective head pressure control valve, won’t
bypass
(page 273)
Defective fan cycle control, stuck closed
(page 273)
Water Cooled Condensers
Water Regulating Valve out of adjustment
Water Regulating Valve Defective
Other
Undercharged
Wrong type of refrigerant
Non-Manitowoc components in system
Liquid line/component restricted