EasyManua.ls Logo

Manitowoc Indigo Series - SUCTION PRESSURE LOW CHECKLIST

Manitowoc Indigo Series
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number Preliminary 6/11 171
SUCTION PRESSURE LOW CHECKLIST
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
(page 162)
Discharge Pressure
Discharge pressure is too low and is affecting low
side – refer to “Freeze Cycle Discharge Pressure
High Checklist” (page 167)
Improper Refrigerant Charge
Undercharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
Improper water supply over evaporator – refer to
“Water System Checklist” (page 163)
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of
refrigeration system
TXV starving - continue the table