IB MODELS - ICE FORMATION PATTERN
Tubing routing for Ice Beverage evaporators is
different. The evaporator outlet is moved lower on the
evaporator.
• IB600 and IB800 evaporators outlets exit roughly
1/2 way down the evaporator. Extremely Thin at
the Evaporator Outlet will first be visible near the
middle of the evaporator
• IB1000 evaporator outlet is roughly 3/4 of the way
down the evaporator. Extremely Thin at the
Evaporator Outlet will first be visible near the
bottom and then the right side of the evaporator.
Extremely Thin at the Evaporator Inlet remains the
same as the other models and will first be visible
several inches above the bottom of the evaporator.