EasyManua.ls Logo

Manitowoc Indigo Series - I0520 W

Manitowoc Indigo Series
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
318 Part Number Preliminary 6/11
I0520W
Self-Contained Water-Cooled Model
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
70/21 9.1-10.7 10.9-12.7 11.7-13.7
1-2.5
80/27 9.4-11.0 11.2-13.1 12.1-14.1
90/32 9.6-11.3 11.6-13.5 12.5-14.5
100/38 9.9-11.6 11.9-13.9 12.9-15.0
110/43 10.2-11.9 12.3-14.3 13.3-15.5
Air Temp. Around Ice
Machine °F/°C
Water Temperature °F/°C
1
1 Based on average ice slab weight of 3.4 - 3.9 lb
50/10 70/21 90/32
70/21 460 395 370
80/27 450 385 360
90/32 440 375 350
100/38 430 365 340
110/43 420 355 330
Air Temp
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
2 Water regulating valve set to maintain 220 psig
3 Condenser Water Usage = 190 gal/100 lb ice @ 90°/70°F
70/21 220-250 52-30 160-190 85-100
80/27 225-265 56-30 170-190 90-110
90/32 225-270 62-31 170-195 95-115
100/38 225-275 65-32 170-205 100-102
110/43 235-280 65-32 170-205 100-120

Table of Contents

Other manuals for Manitowoc Indigo Series

Related product manuals