Page #62 background imageLoading...
Page #62 background image
62 Part Number 80-1230-9 10/10
SN012/SN020/SF0400/SN0450/SF0600/SN0650/
SF0900/SN0950/SF1200/SN1250
Cleaning & Sanitizing Procedure
Ice machines that are heavily scaled or have not been
cleaned on a regular basis will need to run the Heavily
Scaled Cleaning Procedure before this one. Failure to
do so may result in binding of the auger as the lime
scale releases from the auger and evaporator barrel.
Ice machine cleaner is used to remove lime scale or
other mineral deposits. Ice machine sanitizer is used
to remove algae or slime.
Step 1 Remove panels and set the ICE/OFF/CLEAN
toggle switch to the OFF position.
Step 2 Turn off the water supply to the ice machine.
Step 3 Remove all ice from the bin.
Step 4 Place ICE/OFF/CLEAN toggle switch in the
CLEAN position. The dump valve will open and drain
the water from the evaporator and reservoir.
Step 5 Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in
the OFF position.
!
Caution
Use only Manitowoc approved Ice Machine
Cleaner part number 000000084. It is a violation
of Federal law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.

Table of Contents

Other manuals for Manitowoc QF0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QF0400 and is the answer not in the manual?

Manitowoc QF0400 Specifications

General IconGeneral
BrandManitowoc
ModelQF0400
CategoryIce Maker
LanguageEnglish

Related product manuals