Preventative Maintenance
Ice machine cleaner is used to remove lime scale or
other mineral deposits. It is not used to remove algae
or slime. Refer to “Sanitizing Procedure” for removal of
algae and slime. To initiate a cleaning cycle using
Manitowoc’s Cleaning Technology use the following
procedure.
Step 1 To start a cleaning cycle, move the toggle
switch to the CLEAN position. Water will flow through
the water dump valve and down the drain.
Step 2 Remove the cover from the top of the ice
chute. Wait about one minute then add the proper
amount of Manitowoc Ice Machine Cleaner and re-
install cover.
Use only Manitowoc approved Ice Machine
Cleaner part number 000000084. It is a violation
of Federal law to use these solutions in a manner
inconsistent with their labeling. Read and
understand all labels printed on bottles before
use.
Model
Amount of Cleaner
Part Number 000000084
SN12 SN20 2 ounces (60 ml)
SF0400 SN0450 2 ounces (60 ml)
SF0600 SN0650 3 ounces (90 ml)
SF0900 SN0950 6 ounces (180 ml)
SF1200 SN1250 8 ounces (240 ml)