14 Part Number 80-1230-9 10/10
NOTE: Model numbers ending in 3 indicate a 3-phase
unit. Example: RFC12853
* Traditional Remotes - condenser is outside,
compressor is inside. The heat is rejected outside.
Line set consists of a high pressure discharge line and
a high pressure liquid line. Only models ending in “N”
use Traditional Remote Condensers.
** RFC Remote Condensing Unit - compressor,
condenser, accumulator and head pressure control
valve outside. Line set consists of a low pressure
suction line and a high pressure liquid line. Only
models ending in “C” use RFC Remote Condensing
Units.
HOW TO READ A MODEL NUMBER
Personal Injury Potential
The ice machine must be attached to the adapter
and dispenser to prevent the ice machine from
falling. Mounting brackets are provided with all
Nugget ice machines.