158 Part Number 80-1505-3 6/11
Freeze Cycle Discharge Pressure Low Checklist
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
page 151
Improper Refrigerant Charge
Undercharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
High side refrigerant lines/component restricted
(before mid-condenser)
Defective head pressure control valve
Defective fan cycle control
Water regulating valve incorrectly set (CVD1486
only)
NOTE: Do not limit your diagnosis to only the items
listed in the checklists.