Part Number 80-1505-3 6/11 93
G. Remove the water pump.
Note position of water pump outlet, and then
disconnect vinyl hose from the pump outlet.
Rotate the thumbscrew that secures the pump to
the bulkhead 1/4 turn clockwise.
Rotate the water pump assembly 1/4 turn
counterclockwise.
Lower the pump assembly into the evaporator
compartment.
Disconnect the water pump power cord.
Remove water pump assembly from ice
machine.Do not soak the water pump motor in
cleaner or sanitizer solution
H. Remove the bin thermostat probe
Loosen the 2 screws that holds the probe in place.
The probe can easily be cleaned at this point
without complete removal.
NOTE: Proceed to page 101, Step 7.