Part Number: 040006847 12/19 27
n
Warning
Risk of Electric Shock - For hard wired (wired without
a plug) machine, it must be properly grounded and
connected to the field wiring terminal in accordance
with all applicable national and local electrical codes
by a qualified electrician. Before connecting wires,
disconnect power at the electrical disconnect and
lock out to prevent accidentally energizing. Connect
all electrical wiring before use—do not energize ice
machine until installation is complete.
1. Wiring – Connect the three supply lead wires (Blue,
Brown, and Yellow/Green) to the field wiring terminal,
“L”, “N”, and “G”, and the Yellow/Green wire must
connect to the “G” (ground).
2. After connecting the wiring to the terminal strip, the
supply lead must be secured to the cabinet with a
strain relief near the terminal strip.
3. Verify wiring is contained in the electrical wiring box.