Water System Checklist
A water-related problem often causes the same symptoms
as a refrigeration system component malfunction.
Water system problems must be identified and eliminated
prior to replacing refrigeration components.
WATER AREA (EVAPORATOR) IS DIRTY
Clean as needed
WATER INLET PRESSURE IS NOT BETWEEN 1.4 AND 5.5
BAR (20-80PSI)
Install a water regulator valve
INCOMING WATER TEMPERATURE IS NOT BETWEEN
1.7 °C AND 32.2 °C (35°- 90°F)
Hot water does not enter the ice machine
WATER FILTRATION IS PLUGGED (IF USED)
Replace the filter element or install a new water
filtration system
HOSES, FITTINGS, ETC., ARE LEAKING WATER
Repair or replace leaking parts
WATER INLET VALVE IS STUCK OPEN OR CLOSED
Clean/replace as needed
WATER IS SPRAYING OUT OF THE SUMP TROUGH AREA
Stop the water spray
UNEVEN WATER FLOW ACROSS THE EVAPORATOR
Clean the ice machine