64 Part Number: 040006847 12/19
Suction Pressure Low Checklist
Improper Installation
Refer to “Installation” section
Discharge Pressure
A high discharge pressure will affect the suction
pressure. Refer to “Discharge Pressure High Checklist”
Improper Refrigerant Charge
Undercharged
Wrong type of refrigerant
Other
Improper water supply over evaporator. Refer to
“Water System Checklist”
Loss of heat transfer from tubing on back side of
evaporator
Restricted/plugged liquid line drier
Restricted/plugged tubing or capillary tube in suction
side of refrigeration system
TXV starving
Moisture in refrigeration system
NOTE: Do not limit your diagnosis to only the items listed
in the checklists.