outputting the "H" signal; (If the 121 pin continues to be
in the "L" state for 2 seconds or more after the power is
turned ON, the Power Amp circuit is having a problem.)
3) Check that the speaker cable connected to the product
is not in contact and shorting out.
4) The Microprocessor 25 pin (Power Down) is outputting
the "H" signal when the power is turned ON. (If the
25pin continues to be in the "L" state after the power
is turned on, the MAIN PWB circuit , the IC96 and its
adjacent circuits are developing an abnormality.)
NOTE : HOW TO RECOVER FROM SYSTEM ERROR
(STANDBY LED flickering)
The product can recover by turning on
STANDBY on the remote controller after the
above errors are rectified.
Check 3
• Detection of Overcurrent over 200 msec on POWER
AMP (_P CUR FAIL)
When the power is turned on or while the product is
in normal operation, an abnormality occurs with the
POWER AMP, and an overcurrent of 200msec or more
(500msec or more when the power is on) is detected on
the CPU 120 pin.
• Detection of an abnormality on +/-12V Supply or
Power Amp power supply (_P LINE FAIL)
When the power is turned on or while the product is
in normal operation, an abnormality occurs with the
+/-12V supply or POWER AMP power supply with an
abnormality detected on CPU 122 pin.
When errors like the above abnormalities are detected,
the software automatically puts the product into STANDBY
mode, with the STANDBY LED flickering approximately
every 125msec.
NOTE : This SYSTEM ERROR cannot be rectified by users.
In order to power on the product, please do the
following.
: Hold down "SURROUND MODE", "EXIT" &
"CLEAR" at the same time for 3 seconds or
more. However, if any problem remains with
the product, the SYSTEM ERROR will occur
again.
Points to be checked on the circuit
1) Check that the 120 pin (_P CUR FAIL) of the
microprocessor is outputting "H". (If the 120pin is in
the L-state for 500msec or more after the power is
turned on, the POWER AMP circuit is developing an
abnormality.)
2) Make sure that the 122pin of the microprocessor
(POWER LINE FAIL) is "H". (If the 122 pin is in the
L-state for 2 seconds or more after the power is turned
on, the +/-12V power supply or the POWER AMP
power supply is developing an abnormality.)
③ 製品に接続されているSpeaker Cableが+/-又はRear
Panel
等にShortしていないか確認する。
④
電源ON時にマイコンの25pin (Power Down)が"H"に
なっていることを確認する。
(
電源ONしても、25pinが"L"状態で継続している場
合は
MAIN PWB上のIC96及び周辺回路に異常が発生
している
)
復帰操作 :
System Error (STANDBY LED
の点滅)からの復帰
は上記の不具合を改善後リモコンの
STANDBY ON
操作で復帰できます。
Check 3
• Power Amp
の200msec以上の過電流検出
(_P CUR FAIL)
電源ON時又は通常動作時にPower Ampに異常が発生
し、
CPUの120pinでPower Ampの過電流が200msec以上
(Power ON時は500msec以上)検出された場合。
• +/- 12V Supply又は、Power Amp用電源の異常検出
(_P LINE FAIL)
電源ON時又は通常動作時に+/-12V電源又は、Power Amp
用の電源に異常が発生し、CPUの122pinで異常検出がされ
た場合。
上記の様な異常検出がされた場合は、製品を
STANDBY状態に
して、
STANDBY LEDを約125 msec間隔で点滅させます。
Note : このSystem ErrorはUserが通常動作に復帰させること
は出来ません。製品の電源を
ONさせる場合は次の操作
を行います。
復帰操作 :
"SURROUND MODE" + "EXIT" + "CLEAR"
ボタン
を同時に押して
3秒以上保持する。
但し、製品に不具合が残っている場合は再び
SYSTEM ERRORが働きます。
回路上の確認箇所
①
電源ON時にマイコンの120pin (_P CUR Fail) が "H"
になっていることを確認する。
(120pinが電源ONしてから500 msec以上"L"状態が
継続している場合は
POWER AMP回路に異常が発生
している
)
② 電源ON時にマイコンの122pin (Power Line Fail)が
"H"
になっていることを確認する。
(122pin
が電源ONしてから2秒以上"L"状態が継続し
ている場合は
+/-12V電源又は、Power Amp用の電源
に異常が発生している
)