Each input of the balcony photovoltaic integrated machine is only allowed to connect one
photovoltaic module. Do not connect batteries or other power sources. If the installation
environment or connected equipment does not meet the technical parameters required by the
balcony photovoltaic integrated machine, please stop using the balcony photovoltaic integrated
machine.
Do not damage the grounding conductor.
Do not operate the equipment without an installed grounding conductor.
If the equipment needs to be repaired, please be sure to use qualified and compliant parts for
repair. The relevant parts must be installed by an authorized contractor or an authorized service
representative of Marstek Energy Co., Limited. and the relevant parts can only be used for
their intended purpose.
If the on-site installation environment does not meet the standard installation conditions, please
inform the manufacturer in advance.
After the balcony photovoltaic integrated machine is disconnected from the public power grid,
some parts of the balcony photovoltaic integrated machine may still be energized. Please be
careful and beware of electric shock. Before touching the balcony photovoltaic integrated
machine, please ensure that the surface temperature of the device is safe and the voltage
potential of the entire device is within the safe range.
Electrical installation and maintenance work should be completed by qualified electricians, and
wiring should comply with local regulations.
Please check the terminal screws of the equipment regularly to make sure they are tightened and
not loose.
The grounding impedance of the equipment should meet the requirements of local electrical
standards.
The equipment should be permanently grounded. Before operating the equipment, check the
electrical connection of the equipment to ensure that the equipment is reliably grounded.
Using cables in high temperature environments may cause aging and damage of the insulation
layer. The distance between the cables and the heating device or the periphery of the heat source
area should be at least 30 mm.
All cables must be securely connected, well insulated, and of appropriate specifications.
Cable troughs and wire holes should have no sharp edges, and the cable conduits or wire holes
must be protected to prevent the cables from being damaged by sharp edges, burrs, etc.
When laying the power cord, it is strictly forbidden to make loops or twists. If the power cord is
found to be insufficient, it must be replaced. It is strictly forbidden to make joints or welding
points in the power cord.
The selection, installation and routing of cables must comply with local laws, regulations and
specifications.