14 MAC 600/E
Adjustment (AdJ)
The adjustment menu provides manual control for making mechanical adjustments. These should only be performed by a
qualified technician. The menu provides functions to reset the fixture (
RST), turn on and off the lamp (L ON, LoFF), con-
trol all effects in the head (HEAd), and move the head to the home and extreme positions (
PATI). The HEAd submenu
contains functions to:
•move
ALL effects to the OPEN, SPOS (sensor position), and APOS (adjustment position - requires special tool).
• move each effect individually to the open, sensor, and adjustment positions. The shutter has a closed position instead of
a sensor position.
Test sequences
Test sequence (TSEQ)
Run a general test of all effects.
Printed circuit board test (SPEC/ PCBT)
3 tests of the circuit board for service use.
Factory test (SPEC/ FTST)
An effects test (WTST), a movement test (MTST), and a sensor test (STST) used for factory quality control. The sensor
test includes programs for testing sensors on the effect wheels.
Utilities
Calibration (CAL)
The calibration menu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute for
mechanical adjustment. Pan (
P OF), tilt (T OF), dimmer (d OF), cyan (C OF), magenta (M OF), and yellow (Y OF)
may be selected and adjusted from 1 to 255 with the arrow keys. Press [ENTER] to save the calibration.
Reset default offsets (SPEC/dFOF)
Reset all calibrations to their factory defaults. Select dFOF and press [ENTER] when SURE is displayed, or press [MENU]
to escape.
Reset default personality settings (SPEC/ dFSE/ FACT)
Return all personality settings (not calibrations) to their factory defaults. Select FACT and press [ENTER] when LOAD is
displayed.
Custom configurations (SPEC/ dFSE/ CUS1, CUS2, CUS3)
Save and load 3 sets of custom configurations. To save a custom configuration, adjust the settings as desired, go to CUS1,
CUS2, or CUS3 and press [ENTER] when SAVE is displayed. To load a custom setting, select it and press [ENTER]
when
LOAD is displayed.
Upload mode (UPLd)
Upload mode prepares the MAC 600/E to receive control software. It is normally engaged automatically by the upload device.
In certain circumstances, however, you may have to set upload mode manually as described under “Updating software” on
page 19.