IS 24 - 27 - 25T - 30T - 34T
- 18
GB
GB
2.3 TECHNICAL CHARACTERISTICS TABLE
(1)
Limited - time running power (LTP) ISO 8528-1
It is the maximum power that, under the environment conditions established by the norm ISO 3046/1, the generator group it is able to disburse for
a maximum of 500 hours for year, of which a maximum of 300 hours among the interval of maintenance prescribed by the builder. It is accepted
the operation to this power conditions the duration of the group.
An overload of the 10% is admitted only for regulation.
(2)
Prime power (PRP) ISO 8528-1
It is the available maximum power for a variable power cycle that the generator group is able to disburse for a boundless number of hours for year
among the interval of maintenance prescribed by the builder and under the environment conditions established by the norm ISO 3046/1. The middle
power during a period of 24 hours, doesn't have to exceed 80% of the PRP.
An overload of the 10% is admitted only for regulation.
MAX POWER (LTP)
26 29 28 31 36,2
kVA
CONTINUOUS POWER (PRP)
24 27 25 28 33,7
kVA
Φ
MAX TILT OF USE
(PERIODICAL 3 min)
MAX TILT OF USE (CONTINUOUS)
SEA WATER PUMP
L/min - gal/min
DISPLACEMENT
cm
- in
MAX POWER HP - kW
CYLINDERS / HEAD MATERIAL
COOLING
COMBUSTION AIR VOLUME
m
/min - cfm
625 - 1388.8
47 - 35
4
±
±
MODEL
GENERAL FEATURES
IP 23
40 - 104
IS 24 IS 30TIS 25T
28 - 7,40
1225 - 48.2
630 - 24.8
810 - 31.9
30°
25°
IS 27 IS 34T
50
-5 - 23
1000 - 3280
CHAST IRON - ALLUMINIUM
1500
CENTRIFUGAL / MECCANICAL
ENGINE
4 STROKE
YANMAR
4TNV 98
3319 - 202.5
NATURAL
DIESEL
DIRECT
ELECTRIC
700 - 27,5
WATER / WATER
FORCED
10,8
SYNCHRONOUS, SELF-REGULATED
ALTERNATOR
12
(negative pole to ground)
ELECTRIC
12 - 1,2
12 - 80
10,5 - 2.77
2,5 - 88.3
12 - 40
STOP SOLENOID VALVE