PROTON 206/308 V1 System Manual 25
Step 3
Use following command to enable/disable CDC for incoming calls:
3333-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC for incoming calls for all stations:
3333-*-Day Time-Night Time
By default, CDC for incoming calls is disabled during day time and night time.
Step 4
Use following command to enable/disable CDC warning beeps without disconnection:
3334-Station-Day Time-Night Time
Where,
Station is from 21 to 28.
Use following command to enable/disable CDC warning beeps without disconnection:
3334-*-Day Time-Night Time
By default, CDC warning beeps are enabled during day time and night time.
Step 5
Timers of Relevance:
Disconnection time should be programmed for different call types using following table:
Examples:
Program CDC for incoming calls on station 23 during daytime for 4 minutes. The system should give me beep
after 3.5 minutes.
Use following commands:
3333-23-1-0
217-28-210
217-29-30
Program CDC for STD calls on station 21 during nighttime for 5 minutes. The system should give me beep after
4 minutes.
Use following commands:
3332-21-0-1
217-27-240
217-29-60
Day Time Night Time Meaning
0 0 CDC is disabled
1 1 CDC is enabled
Day Time Night Time Meaning
0 0 CDC is disabled
1 1 CDC is enabled
Command Description Range Default Unit
217-26-Timer CDC local warn timer 001-255 240 Sec
217-27-Timer CDC STD warn timer 001-255 120 Sec
217-28-Timer CDC incoming warn timer 001-255 240 Sec
217-29-Timer CDC good-bye timer 01-99 60 Sec