Parameter VALUE
L02
0 Funcon not acve
1 Enable Hz minimum
L03
0 Funcon not acve
1 Funcon acve only in cooling mode
2 Funcon acve only in heang mode
3 Funcon acve only in sanitary mode
4 Funcon acve in cooling and sanitary mode
5 Funcon acve in heang and sanitary mode
6 Funcon in cooling and heang mode
7 Funcon always acve
With the funcon acve, the output and power of the unit are limited, for addional informaon see the installer user manual.
17. MINIMUM HZ FUNCTIONS
When the funcon is acvated, the power of the unit is increased, for informaon contact the company.
18. AUXILIARY RESISTANCES
In some system soluons it may be necessary to use an integraon heater for the system and/or for the sanitary area. This is an addional re-
source for heang in case the compressor cannot meet the set in a reasonable me. The resistor controller only operates in heang mode and
if r10 = 1.
To dene how the integraon resistors are to operate, parameter r24 must be se:
• r24 = 0 for integraon resisitors not used;
• r24 = 1 for use of system integraon resisitor;
• r24 = 2 for use of sanitary integraon resisitance;
• r24 = 3 for use of both the system integraon resistor and the sanitary integraon resistor.
SYSTEM RESISTANCE
The system resistance must be connected to the digital output DO3 and can be congured by seng parameter H81 = 22.
If the regulaon temperature remains lower than the hot water set-point (°C) for a me equal to r12 the integraon resistor is acvat-
ed according to the operaon of the machine in the combined or replacement bands.
The resistor is also acvated if the control temperature remains below the water set-point (°C) and the machine is in lockout due to
the intervenon of an alarm. It switches o when the machine exits the alarm block.
Seng r21 = 1, during the defrost cycle, if required (temperature lower than Hea - r11), the system resistor is acvated without waing for the
me dened by r12.
The resistor switches o when the set-point is reached (also taking into account any oset set with parameters r29 or r30).
Parameter VALUE
H81 22 System integraon resistance
r10 1 Enabling of system resistors
r11 5 (default) Delta resistances in system integraon (in tenths of °C)
r12 10 (default) System integraon acvaon delay (in minutes)
r21 1 Enabling resistors during defrosng
r24 1/3 Type of use resistors
SANITARY RESISTANCE
This funcon can be acvated as an alternave to the system integraon resistance. The DHW resistance must be connected to digital output
DO3 and can be congured by seng parameter H81 = 26, in addion the DHW funcon must be acve.
The resistance is acvated if the producon of domesc hot water lasts longer than r16 (minutes) or if the machine goes into lockout due to
the intervenon of an alarm. It switches o when the machine nishes DHW producon (also taking into account any oset on the set-point set
with parameter r31).
Parameter VALUE
H81 26 DHW integraon resistor
r15 1 Enabling of DHW resistors
r16 10 (default) Sanitary integraon acvaon delay (in minutes)
r24 2/3 Type of use of resistance
INDIVIDUAL SYSTEM/HEALTH INTEGRATION RESISTENCE
Conguring the DHW resistance it is also possible to use it as a system resistor, by seng the parameter r15 = 2 and r24 = 3.
In this way, in the event of a request for system integraon, the resistance declared as DHW integraon is acvated, thus making it possible to
have a single integraon resistance for the system, DHW and defrosng.