EasyManua.ls Logo

Maxon GPTLR-44 - Electrical Values and Torque Specifications; Solenoid, Valve, and Lock Valve Specs

Maxon GPTLR-44
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
87
TABLE 87-1
GPTLR ELECTRICAL VALUES & TORQUE SPECIFICATIONS
SYSTEM DIAGRAMS
Solenoid Switch 12V 24V
Coil resistance:
5.4Ω @70ºF. ±15% 20.1Ω @70ºF. ±15%
Ampere:
2.2A 1.2A
Coil terminal torque: 10-15 lb-in max.
Contact terminal torque: 30-35 lb-in max.
Solenoid Valves (A, S1, & S2)
Coil resistance:
4.0Ω @ 70ºF. ±15% 26.7Ω @ 70ºF. ±15%
Ampere:
3A, 2.5A @10V
Coil terminal torque: 15-45 lb-in max.
Valve cartridge torque: 25-30 lb-ft max.
Coil nut torque: 15-45 lb-in
Solenoid Lock Valve
Coil resistance:
8.0Ω @ 70ºF. ±15% 30Ω @ 70ºF. ±15%
Ampere:
1.5A 0.8A
Coil nut torque: 3-4.5 lb-ft max.
Valve cartridge torque: 18.5-22 lb-ft max.
Digital Cycle Counter
Input voltage
4V - 30V 4V - 30V
Ampere <2mA
Ground Cable
Cap screw torque: 24 lb-ft max.

Other manuals for Maxon GPTLR-44

Related product manuals