11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
89
Pre-Installation Inspection:
Correct model Correct capacity
Correct platform size Correct options
Manuals & decals
Structural Inspection:
Inspect alignment of fi nal assembly
Inspect pump box secure mounting
Inspect all installation welds
Check roll pins, bolts and fasteners
Inspect tightness of hardware used to secure
liftgate to vehicle.
Ensure platform ramp tip touches ground or is
not more than 1/4” off the ground.
Ensure bottom of underride tube is not more
than 21-1/2” off the ground and not more than
11” forward of the extreme rear of vehicle.
Hydraulic Inspection:
Proper fl uid level (See CHECKING
HYDRAULIC FLUID step in this manual.)
Check hydraulic fi ttings in pump box for leaks
Check hydraulic line connections for leaks
Electrical Inspection:
Check power/charge plug and terminal
Check for tight wire connections
Circuit breaker (150A) installed in battery box
(if equipped) or by truck/tractor battery.
Ensure batteries are fully charged, all cable
connections are tight & tiedowns are tight.
Inspect all solenoid connections
Check all wiring harness connections
Check electrical cable connections are tight &
secure.
Operation Inspection:
Check operation of all main and optional
control switches.
GPTLR-25 or GPTLR-33 only
Unloaded platform lowers in 6 sec.
Unloaded platform raises in 15 sec.
GPTLR-44 or GPTLR-55 only
Unloaded platform lowers in 10 sec.
Unloaded platform raises in 25 sec.
All GPTLR: Unloaded platform raises and
lowers evenly. At the extension plate, platform
must not be more than 1/4” uneven, from side
to side.
All GPTLR: Breakaway force to unfold plat-
form is 30 lb-ft maximum. Breakaway force to
fold platform is 40 lb-ft maximum.
All GPTLR: Platform stores securely under
vehicle body
Check if cycle counter works
Decals in correct location and legible
Verify all lights are operational
(For lights supplied by MAXON only)
Platform lights turn ON when platform is un-
folded, and turn OFF when platform is stowed.
Taillights, stop lights, turn lights, and backup
lights turn ON and OFF correctly.
NOTE: The following times are for 55” bed
height, aluminum platform and
fl ipover, Exxon Univis HVI-13 oil,
& temperature at 70°F. Times are
for reference only and may vary for
larger platforms, smaller platforms,
or temperature changes.
Model:______________________ Date: ____________________
Serial Number: _______________ Technician: _______________
PRE-DELIVERY INSPECTION FORM
Important! This pre-delivery checklist is to aid the installer in confi rming the proper installation of
this Maxon product. It is not a comprehensive list and does not replace the use of the installation
manual. The installer is responsible for following all instructions in the installation manual.