STEP 6 - CONNECT GROUND CABLE
CONNECTING EXTERNAL
GROUND CABLE
FIG. 36-1
INSERTING GROUND CABLE
THROUGH GROMMET
FIG. 36-1A
BOLTING GROUND CABLE TO PUMP
FIG. 36-1B
NOTE: To ensure power unit is correctly grounded, connect 2 gauge ground cable
to grounding connection on pump.
1. Insert external ground cable (parts box)
through grommet on pump mounting
plate (FIGS. 36-1 & 36-1A).
2. Bolt ground cable to ground connection
on pump using existing bolt (FIGS. 36-1
& 36-1B).
3. Form a drip loop on the ground
cable where it enters the grommet
from outside the pump mounting
plate (FIGS. 36-1 & 36-1B).
TERMINAL LUG
TERMINAL LUG
(EXTERNAL GROUND
(EXTERNAL GROUND
CABLE)
CABLE)
GROUND
GROUND
CABLE
CABLE
GROMMET
GROMMET
PUMP MOUNTING
PUMP MOUNTING
PLATE
PLATE
NOTE: Electrical lines must be run into pump box through sealing grommets
(FIG. 36-1A). To ensure a good seal on the electrical lines, never
cut the sealing grommets.
GROUND
GROUND
CONNECTION
CONNECTION
BOLT
BOLT
DRIP LOOP
DRIP LOOP