Form No.3351-1A-01A
E
E-1
COOLING SYSTEM
ABBREVIATIONS E-1...........................
OUTLINE E-1..................................
OUTLINE OF CONSTRUCTION E-1............
SPECIFICATIONS E-1........................
COOLING MECHANISM E-2.....................
STRUCTURAL VIEW AND COOLANT FLOW
DIAGRAM E-2..............................
RADIATOR E-3...............................
ABBREVIATIONS
ATF Automatic transaxle fluid
OUTLINE
OUTLINE OF CONSTRUCTION
FP, FP (HiĆpower)
D The construction and operation of the cooling system for Australian specs. are the same as those of the
current 323 (BJ) FP engine model for each respective specification. (Refer to 323 Training Manual
3327-10-98G.)
Due to the change in vehicle body shape, the radiator shape has also been changed from the current 323
(BJ).
SPECIFICATIONS
Specification
FP
Cooling system WaterĆcooled, forced circulation
Coolant capacity (Approximate quantity) (L {US qt, lmp qt.}) 7.5 {7.9, 6.6}
Water pump Type Centrifugal, VĆribbed belt driven
Type Wax, bottomĆbypass
InitialĆopening temperature (°C{°F}) 80Ċ84 {176Ċ183}
FullĆopening temperature (°C{°F}) 95 {203}
FullĆopening lift (mm {in}) 8.5 {0.33} min.
Radiator Type Corrugated fin
Radiator cap opening pressure (kPa {kgf/cm
2
, psi}) 94Ċ122 {0.95Ċ1.25, 13.6Ċ17.7}
Type Electrical
Cooling fan
Number 4
Outer diameter mm {in} 300 {11.8}