30119-50 Rev. 2.2 | 23JUL2020
Page 17
Output Wiring Connection
3.3 LCD Output Symbol Clarications
The 4-20mA full scale is not dened and the
4-20mA loop is either powered or not powered.
There is no 4-20mA output and the 4-20mA
symbol is o.
The 4-20mA full scale is dened and the 4-20mA
loop is powered.
There is a 4-20mA output and the 4-20mA
symbol is on.
The 4-20mA full scale is dened and the 4-20mA
loop is powered, but the output value is over
21.5mA.
There is a 4-20mA output and the 4-20mA
symbol is ashing.
The pulse increment value is not dened. There is no pulse output and the PULSE symbol
is o.
The 4-20mA loop is not powered, the pulse
increment value is dened and the pulse type
is set as an optically-isolated open collector or a
relay switch.
There is no pulse output and the PULSE symbol
is ashing.
The 4-20mA loop is not powered, the pulse
increment value is dened and the pulse type is
set as an open collector.
There is a pulse output and the PULSE symbol
is on.
The 4-20mA loop is powered, the pulse increment
value is dened and the pulse type is set as an
optically-isolated open collector or a relay switch.
There is a pulse output and the PULSE symbol
is on.
The 4-20mA loop is powered, the pulse increment
value is dened and the pulse type is set as an
optically-isolated open collector or a relay switch,
but the output frequency is greater than the limit
of the selected pulse type.
There is a pulse output and the PULSE symbol
is ashing.
The battery level is ok. The “BAT symbol is o.
The 4-20mA loop is either powered or not
powered, and battery level meets low battery
criteria.
The “BAT symbol is on.
SCENARIO
RESULT
FC101 Screen Symbols
Figure: 28
PULSE SYMBOL
BATTERY SYMBOL
FLOW RATE UNIT
FLOW TOTAL MULTIPLIER FLOW TOTAL UNIT
FLOW TOTAL DIGITS
FLOW RATE DIGITS
4-20mA SYMBOL