SPECIFICATIONS
20
DLRO 10 DLRO 10X
Maximum Lead Resistance 100 mΩ total for 10A operation irrespective of battery condition.
Voltmeter Input Impedance > 200 kΩ
Hum Rejection Less than 1% ± 20 digits additional error
with 100 mV peak 50/60 Hz. on the potential leads.
Warning will show if hum or noise exceeds this level.
Data Transfer Real Time or from storage via RS232
Storage 700 tests
Memo Field Up to 200 characters per test via
integral alphanumeric keypad.
Battery Capacity 7 Ah NiMH rechargeable.
Life Typically 1000 x 10 A tests before recharge
Recharge Via External 90V - 260 V 50/60 Hz charger or from 12 to 15 V d.c. supply
Charging Time 2.5 hours to 90% capacity, 4 hrs for full charge
Temperature Operation +5°C to +45°C (41°F to 113°F) at full specification.
-10°C to +50°C (14°F to 122°F) at reduced acuracy
Storage -30°C to +70°C (-22°F to 158°F)
Calibration 20°C (68°F)
Coefficient <0.01% per oC from 5°C to 40°C (<0.006% per °F from 41°F to 104°F)
Standard charging 0°C to +45°C (32°F to 113°F)
Fast charging +10°C to +45°C (50°F to 113°F)
Humidity Max 90% RH @ 40°C (104°F) non-condensing
Altitude Max 2000m (6562 ft.) to full safety specifications
Safety In accordance with IEC61010-1 600 V Category III - only when DH6 leads are used
EMC In accordance with IEC61326-1
Operation inaccuracies Refer to www.megger.com
Dimensions 220 x 100 x 237 mm (8.6 x 4 x 9.5 in)
Weight 2.6 kg (5 3/4 lb.) including battery module