EasyManua.ls Logo

Megger DLRO-10X - Specifications; Ranges

Megger DLRO-10X
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ranges
DLRO 10 DLRO 10X
Display Measurement 4
1
/
2
digit seven segment LED
Range and Safety LED Indication
Measurement Mode Manual, Auto, Continuous, Inductive Manual, Auto, Continuous,
Inductive, Unidirectional.
Control Fully Automatic Fully Automatic with manual
override of maximum current
Speed <3s for forward & reverse current and to display average
Test Method Single cycle reversing d.c. ratiometric measurements and average result calculated.
Test Current Accuracy 10%
Output Current Stability <10 ppm per second @ 10 mA
<100 ppm per second at higher currents
SPECIFICATIONS
19
Large backlit LCD
Full Scale Resolution Accuracy Full Scale Volts Test Current
Resistance ResistanceInduction Induction
1,9999 mΩ
19,999 mΩ
199,99 mΩ
1,9999 Ω
19,999 Ω
199,99 Ω
1999,9 Ω
0,1 µΩ
1 µΩ
10 µΩ
100 µΩ
1 mΩ
10 mΩ
100 mΩ
±0,2%±0,2 µΩ 20 mV
20 mV
20 mV
20 mV
20 mV
20 mV
200 mV
20 mV
200 mV
200 mV
200 mV
200 mV
200 mV
10 A
1 A
100 mA
10 mA
1 mA
100 µA
100 µA
1 A
1 A
100 mA
10 mA
1 mA
100 µA
±0,2%±2 µΩ
±0,2%±20 µΩ
±0,2%±0,2 mΩ
±0,2%±2 mΩ
±0,2%±20 mΩ
±0.2%±0.2 Ω

Table of Contents