19
section. Press and hold the button for 1 second or
more to activate SORT™ mode with LCD annunciators
turned on. The meter beeps when a stable
reading is captured, and the last captured reading,
together with a counter, will be automatically held and
displayed. Press the button momentarily to cycle through
the Maximum (MAX), Minimum (MIN), Maximum minus
Minimum (MAX-MIN), and Average (AVG) readings. Press
the button for 1 second or more to exit SORT™ mode.
S O R T™ senses a stable measurement, beeps, captures it
for comparison & display, then stores the maximum and
minimum readings, together with the event numbers, in
memory for later display. The average feature calculates all
the readings taken and displays the true average value
together with the number of events counted. This simplifie s
MAX and MIN values sorting, MAX-MIN & AVG values
calculation, and quantity counting in component inspection.
When used with relative % change function, readings will
be displayed in terms of percentage deviation.
Note: 1. Auto Power Off feature will be disabled
automatically in this mode.
Back Light Feature (M8037 only)
Press and hold the button for 1 second or more to
activate backlight. The backlight will automatically switch
off 42 seconds after each activation to extend battery life.
When the backlight is already on, press and hold the
button again to reset the automatic off timing.
Line Filter Frequency 50 Hz or 60 Hz Select
The line filter frequency can be selected as a power-on
option. Press the button while turning the meter on
to display the set frequency. Press the button for
50 Hz or press the button for 60 Hz selection. Then
press the button to store the selected frequency.
Selecting the appropriate line filter frequency to cope with
your line frequency can maximize the meter’s noise
rejection ability. This is normally only available in
expensive bench-top multimeters.
Set Beeper Off
The beeper feature can be disabled manually as a power-
on option by pressing the button while turning the