The MIT300 series variants have the following features:
MIT300 MIT310 MIT310A MIT320 MIT330
Insulation testing
1 kV Insulation range
nnnn
500 V Insulation range nnnnn
250 V Insulation range nnnnn
Insulation test full scale 999 M 999 M 999 M 999 M 999 M
Insulation limit alarm
0.01 M to 1 G
nn
Continuity
Voltmeter range
(600 V digit)
nnnn
Continuity buzzer n n nnn
Adjustable buzzer
threshold 1 to 20 nn
Audible buzzer disable nn
Lead null to 9.0
(0.5 for MIT310A) n n 0.5 n n
Stored test lead null nnnnn
Resistance
10 to 1M resistance
range
nn
INTRODUCTION GENERAL DESCRIPTION
4
Thank you for purchasing the Megger Insulation Tester.
For your own safety and to get the maximum benefit from your
instrument, please ensure that you read and understand the following
safety warnings and instructions before attempting to use the instruments.
This user guide describes the operation and functions of the following:
MIT300 Series of insulation and continuity testers:
MIT300
MIT310
MIT310A
MIT320
MIT330
MIT300_UG_en_V11.qxp 14/1/09 3:03 pm Page 4
www.netzerotools.com
www.netzerotools.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Megger MIT310 and is the answer not in the manual?

Megger MIT310 Specifications

General IconGeneral
BrandMegger
ModelMIT310
CategoryTest Equipment
LanguageEnglish

Related product manuals