EasyManua.ls Logo

Megmeet MV300 Series - Page 183

Default Icon
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
183
Fig. 6-55 Schematic diagram for switching between acceleration/deceleration time 1 and 2
As shown in Fig. 6-55, for accelerating the motor 1, operate at the acceleration time 1, as the A curve
shown in Fig. 6-55 and the acceleration time
15.02
13.0214.11
1
t
P
PP ×
=
. When the output frequency
increases to the switching point P11.14, the acceleration time will switch from P02.13 to P11.02, as the
B curve shown in Fig. 6-55 and the acceleration time
15.02
02.11)14.11(
2
t
P
PPf ×
=
. For deceleration,
operate at the deceleration time 2, as the C curve shown in the figure and
15.02
14.02)15.1114.11(
3
t
P
FPPf ×+
=
, until the output frequency decreases to a frequency
(P11.14-P11.15) lower than P11.14, the deceleration time will switch to the deceleration time 1 from 2
switching value, as the D curve shown in the figure, and
15.02
03.11)15.1114.11(
4
t
P
PPP ×
=
Fig. 6-56 Description of the jog running parameter
Jo
g
runnin
g
fre
q
uenc
y
0.10~50.00 Hz
(
5.00 Hz
)
P11.18
Jo
g
interval time 0.0~100.0s
(
0.0s
)
P11.17
Jo
g
acceleration/deceleration time 0.1~60.0s
(
6.0s
)
P11.16

Table of Contents